深夜福利一区二区,女女同性女同一区二区三区九色 ,我与么公激情性完整视频在线观看,成在人线AV无码免费高潮水

Four reasons analysis of pump vibration

Date of issue:[2020-08-17]     Click through rate:    

There are many reasons leading to the vibration of unit and pump house buildings. Some factors are related and interact with each other.

1. Electrical

The main cause of the unbalance of the generator set and other electrical equipment is the unbalance of the motor and the electrical system. For example, in the operation of asynchronous motor, the radial alternating magnetic pull force between stator and rotor caused by harmonic flux interaction between stator and rotor, or large synchronous motor in operation, the magnetic center of stator and rotor is inconsistent or the air gap difference in each direction exceeds the allowable deviation value, etc., which may cause periodic vibration and noise of the motor.

2. Mechanical aspect

Strong vibration and noise will be produced due to mass imbalance, rough manufacturing, poor installation quality, asymmetric unit axis, swing exceeding allowable value, poor mechanical strength and stiffness of parts, wear and damage of bearing and sealing parts, and resonance between critical speed of water pump and natural frequency of unit.

3. Water power

The uneven distribution of flow velocity and pressure at the pump inlet, the pressure pulsation of the working liquid at the pump inlet and outlet, the flow around, the bias flow and the flow separation of the working liquid at the pump inlet and outlet, as well as the pump cavitation caused by various reasons under non quota conditions are the common causes of pump unit vibration. The rapid change of water pressure and water hammer caused by the dynamic transient processes such as pump start-up and shutdown, valve opening and closing, working condition change and emergency shutdown also often lead to pump house and unit vibration.

4. Hydraulic and other aspects

The unreasonable design of the inlet channel of the unit, the improper submergence depth of the water pump, and the unreasonable start-up and shutdown sequence of the unit will worsen the water inlet conditions, produce vortices, induce cavitation or aggravate the vibration of the unit and pump house. When the unit using the breaking siphon vacuum cut-off is started, if it is difficult to carry the air in the hump section, the siphon time will be too long; the clapper door design of the unit with flap valve cut-off is not reasonable, sometimes open and close, and constantly impact the flap door seat; uneven settlement of the foundation supporting the water pump and motor or poor rigidity of the foundation will also lead to the vibration of the unit.

Technology Department


Address:576 Wuding Road, Jing'an District, Shanghai

E-mail:info@xinguangminggroup.com

av在线揉b| 婷婷色情乱婬一区二区| 蜜臀色一区二区精品| 欧美成人性视频久久久| 中文字幕1区| 骚逼福利视频导航| 五月天在线观看91| 综合一区二区三区蜜臀| 婷婷五月天成人,在线| 大鸡巴抽插骚逼的视频| 激情开心久久精品| 操逼美女爽6| 久久超碰抽插人体| 看老外的大鸡巴日美女的b| 美女喜欢的大鸡巴| 男女搞鸡www| 欧美三级在线中文字幕一区| 亚洲伦理母乳片| 波多野结衣无码视频一区二区三区 | 77777一区二区三区| 亚洲av字幕一区| 韩国人妻激情在线| 又黄又骚的视频日| 骚片日逼| 91刘玥精品一区二区三区| av老司机 在线播放| 中出性感美少妇| 嗯啊好舒服啊欧美国产| 华池县| 丝袜美腿日韩一区AV| 又大又长的鸡巴操| 琼中| 少妇蜜臀aV一区二区三区| 激情黄片A级啪啪二区二区| 激情黄片A级啪啪一区二区| 99久re久热996热99| 欧美逼逼欧美逼逼| 深爱激情久久| 91大神在线观看网| 操逼片中文字幕| 翼城县|